1) If the shaft seal has been removed by the customer 2) Only with shaft stationary (note initialisation time)
Электрические параметры
Operating voltage range:
10 V DC ... 32 V DC
Operating power consumption (no load):
90 mA
MTTFd: mean time to dangerous failure:
300 a (EN ISO 13849-1) 1)
footnote
1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Interfaces
Electrical interface:
Cable, 22-pin, radial, 1.5 m
Ambient data
EMC:
(according to EN 61000-6-2 and EN 61000-6-3) 1)
Enclosure rating:
IP 66 (according to IEC 60529)
Permissible relative humidity:
90 % (condensation of the optical scanning not permitted)
Working temperature range:
-20 °C ... 85 °C
Storage temperature range:
-40 °C ... 100 °C
Resistance to shocks:
50 g (according to EN 60068-2-27)
Resistance to vibration: