Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Performance
Error limits:
± 0.05 °
Measuring step:
90 ° / electronically/number of lines
Initialization time:
40 ms
Pulses per revolution:
1,024
Механические параметры
Mechanical interface:
Blind hollow shaft
Shaft diameter:
8 mm
Mass:
0.2 kg
Start up torque:
0.8 Ncm (+20 °C)
Operating torque:
0.6 Ncm (+20 °C)
Permissible movement axial static/dynamic:
± 0.5 mm, ± 0.2 mm
Permissible movement radial static/dynamic:
± 0.3 mm, ± 0.1 mm
Maximum operating speed:
6,000 /min
Moment of inertia of the rotor:
40 gcm?
Bearing lifetime:
3.6 x 10^10 revolutions
Max. angular acceleration:
500,000 rad/s?
Shaft material:
Metal
Электрические параметры
Electrical interface:
4.5 V ... 5.5 V, TTL/RS422, Cable, 8-pin, universal, 1.5 m
Connection type:
Cable, 8-wire, universal, 1.5 m 1)
Maximum output frequency:
600 kHz
Reference signal, number:
1
Reference signal, position:
90 °, electronically, gated with A and B
Operating voltage range:
4.5 V ... 5.5 V
Load current max.:
30 mA
MTTFd: mean time to dangerous failure:
300 a (EN ISO 13849-1) 2)
footnote
1) The universal cable outlet is positioned in such a way, that it is possible to lay the cable in a radial or axial direction without kinking it 2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Ambient data
EMC:
(according to EN 61000-6-2 and EN 61000-6-3)
Working temperature range:
-30 °C ... +100 °C
Storage temperature range:
-40 °C ... +100 °C, without package
Resistance to shocks:
70 g (according to EN 60068-2-27)
Resistance to vibration:
30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Enclosure rating:
IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Permissible relative humidity:
90 % (condensation of the optical scanning not permitted)