S3000 Standard, Sensor head with I/O module - S30A-7011BA - 1023890
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Функции
Number of simultaneously monitored protective fields: | ? 4 1) |
---|---|
Static protective field switching: | - |
Incremental encoder inputs: | - |
Expanded measured data output (CMS): | - |
footnote | 1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway. |
Технические характеристики
Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
---|---|
Enclosure rating: | IP 65 (EN 60529) |
Protection class: | II (EN 50178) |
Type: | Type 3 (IEC 61496) |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category: | Category 3 (EN ISO 13849) |
Performance level: | PL d (EN ISO 13849) |
PFHd: | 8.0 * 1E-08 (EN ISO 13849) |
TM (mission time): | 20 a (EN ISO 13849) |
Ambient operating temperature: | -10 °C ... +50 °C |
Dimensions (W x H x D): | 155 mm x 185 mm x 160 mm |
Weight: | 3.3 kg |
Scan angle: | 190 ° |
Protective field range: | 7 m |
Maximum warning field range: | 49 m |
Number of field sets: | 1 |
Type of field set: | Dual field sets, Triple field sets |
Number of monitoring cases: | 1 |
Response time: | 60 ms 1) |
Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable |
Distance measuring range: | 49 m |
Number of multiple samplings: | Configurable 2 ... 16 |
Electrical connection: | System plug with or without connecting cable |
Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC |
Number of EDM inputs: | 1 |
Number of reset-/restart inputs: | 1 |
Number of safe outputs: | 2, Safety outputs (OSSD) |
Number of application diagnostic outputs: | 3 2) |
Maximum output current: | 500 mA |
Configuration and diagnostics interface: | RS-232 |
Data interface: | RS-422 |
footnote | 1) Depending on basic response time and multiple sampling 2) Freely programmable, e.g., warning field, contamination, reset required |