Main unit UE45-3S1 - UE45-3S13D33 - 6024912
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Applications
Type of switching amplifier: | Main unit |
---|---|
Safety Switch with mechanical lock: | - |
Two-hand control systems: | - |
Pressure sensitive mats: | - |
Opto-electronic protective devices: | - |
Opto-electronic protective devices without RES/EDM: | - |
Opto-electronic protective devices with RES/EDM: | - |
System part: | Safety relays |
Функции
Input circuit:: | Single- or dual-channel |
---|---|
Reset/restart: | Manual / automatic / configurable |
Технические характеристики
Safety integrity level: | SILCL3 (IEC 62061) SILCL2 (IEC 62061) 1) 2) |
---|---|
Category: | Category 4 (EN ISO 13849) category 3 (EN ISO 13849) 3) 4) |
Performance level: | PL e (EN ISO 13849) PL d (EN ISO 13849) 5) 6) |
B10d parameter: | 4*1E 05 switching cycles (with maximum load) |
PFHd: | 3.0 * 1E-08 2.0 * 1E-08 |
TM (mission time): | 20 a |
Stop category: | 1, 0, EN 60204 |
Width: | 22.5 mm |
Contact type: | Positively driven |
Number of enable current contacts: | 2 |
Number of off-delayed N/O contacts: | 1 |
Delay time: | 0.15 s ... 3 s |
Operating voltage DC: | 24 V DC |
Maximum power consumption DC: | 2.6 W |
Type of output: | Relay contacts |
Rated operating current (voltage): | 4 A (230 V AC) 3600 switching cycles/h 5 A (24 V DC) 360 switching cycles/h 3 A (24 V DC) 3600 switching cycles/h |
Maximum switching current: | 6 A |
Maximum total current: | 12 A |
Mechanical life (relay contacts): | 5*1E 06 switching cycles |
Electrical life (relay contacts): | 2* 1E 06 switching cycles, dependent upon loading, details see operating instructions |
Enclosure rating: | IP 20 |
Ambient operating temperature from ... to: | -25 °C ... 55 °C |
Connection type: | Plug-in terminals |
footnote | 1) 3) 5) For contacts 13/14, 23/24 2) 4) 6) For time contacts 37/38 |