CANopen , MLG, MLG CANopen - MLG1-0440C821 - 1061080
Сделать заказ
Так же Вы можете заказать данную позицию по тел.: +7 (812) 200-96-95
Features
Technology: | Sender/receiver |
---|---|
Task: | Measurement light grid |
Minimum detectable object (MDO): | Parallel beam, 20 mm |
Beam separation: | 10 mm |
Количество лучей: | 45 |
Detection height: | 440 mm |
Configuration: | ESD file |
Performance
Maximum range 1): | 12 m |
---|---|
Minimum range: | Parallel beam: ?0 mm |
Response time 2): | Parallel beam 7.75 ms |
Working range: | 8.5 m |
footnote | 1) No reserve for environmental issue and deterioration of the diode 2) With resistive load |
Interfaces
Data interface: | CANopen |
---|---|
Output type: | 1 x PNP |
Inputs: | 1 x PNP |
Connection type: | Male connector M12, 8-pin |
IO-Link: | - |
Mechanics/electronics
Wave length: | Infrared light 880 nm |
---|---|
Supply voltage Vs: | DC 18 V ... 30 V |
Power consumption sender 1): | 230 mA |
Power consumption receiver 2): | 235 mA |
Ripple: | < 5 Vpp |
Output current Imax.: | 100 mA |
Output load capacitive: | 100 nF |
Output load inductive: | 1 H |
Initialization time: | 1 s |
Dimensions (W x H x D): | 34 mm x 514 mm x 29 mm |
Housing material: | Aluminum |
Indication: | 7-segment display |
Enclosure rating: | IP 65 |
Circuit protection: | Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected |
Weight: | 1.512 kg |
Front screen: | PMMA |
Synchronization: | Cable |
footnote | 1) 2) Without load with 24 V |
Ambient data
Protection class: | III |
---|---|
EMC: | EN 60947-5-2 |
Ambient temperature: | Operation: -25 ... +55 °C, Storage: -40 ... +70 °C |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) |
Shock load: | 10 g / IEC 68-2-29 / 16 ms |
Ambient light immunity: | Direct: ?12,500 lx, Indirect: ?50,000 lx 1) |
footnote | 1) Sunlight |