| Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
|---|
| Enclosure rating: | IP 65 (EN 60529) |
|---|
| Protection class: | II (EN 50178) |
|---|
| Type: | Type 3 (IEC 61496) |
|---|
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
|---|
| Category: | Category 3 (EN ISO 13849) |
|---|
| Performance level: | PL d (EN ISO 13849) |
|---|
| PFHd: | 8.0 * 1E-08 (EN ISO 13849) |
|---|
| TM (mission time): | 20 a (EN ISO 13849) |
|---|
| Ambient operating temperature: | -10 °C ... +50 °C |
|---|
| Dimensions (W x H x D): | 155 mm x 185 mm x 160 mm |
|---|
| Weight: | 3.3 kg |
|---|
| Scan angle: | 190 ° |
|---|
| Protective field range: | 4 m |
|---|
| Maximum warning field range: | 49 m |
|---|
| Number of field sets: | 1 |
|---|
| Type of field set: | Dual field sets, Triple field sets |
|---|
| Number of monitoring cases: | 1 |
|---|
| Response time: | 60 ms 1) |
|---|
| Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable |
|---|
| Distance measuring range: | 49 m |
|---|
| Number of multiple samplings: | Configurable 2 ... 16 |
|---|
| Electrical connection: | System plug with or without connecting cable |
|---|
| Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC |
|---|
| Number of EDM inputs: | 1 |
|---|
| Number of reset-/restart inputs: | 1 |
|---|
| Number of safe outputs: | 2, Safety outputs (OSSD) |
|---|
| Number of application diagnostic outputs: | 3 2) |
|---|
| Maximum output current: | 500 mA |
|---|
| Configuration and diagnostics interface: | RS-232 |
|---|
| Data interface: | RS-422 |
|---|
| footnote | 1) Depending on basic response time and multiple sampling 2) Freely programmable, e.g., warning field, contamination, reset required |
|---|